為了防止製冷劑液體積蓄在壓縮機中,應保證壓縮機殼體底部的溫度大於冷凝溫度。
To prevent the liquid refrigerant accumulation in the compressor, ensure that the temperature at bottom of compressor case is higher than the condensing temperature.
運行電壓必須在額定電壓的±10%範圍之內。
The running voltage shall be within ±10% of the rated voltage.
運行頻率必須在額定頻率的±2%範圍之內。
The running frequency shall be within ±2% of the rated frequency.
壓縮機在傾斜角5°範圍內可以正常運轉。
The compressor shall operate properly with tilting angle below 5°.
禁止壓縮機橫放、倒置、跌落,不要把壓縮機放置在露天,必須將壓縮機存放在-10℃~+65℃的室內。
Do not put the compressor horizontally or put it upside down. Do not let the compressor falls off. Do
not put the compressor in the open air, put the compressor inside the room where the temperatures
為了防止磁鐵退磁,在設計變頻係統時必須保證轉子內的永久磁鐵在任何情況下都不會被退磁;必須使用專用的變頻器,一定不能使用感應電機所用的變頻器或(直接)使用商用電源。
In order to prevent the permanent magnet to be demagnetised, the frequency conversion system must
ensure the permanent magnet not be demagnetised in any situation; use the spec
運行電壓必須在260~350VDC範圍之內。
The running voltage shall be within 260~350VDC.
運行頻率必須在15~120Hz 的範圍之內。
The running frequency shall be within 15~120Hz.